The Magnum 3 stage cart is configured for optimum pure water cleaning, providing 2 - 3 floors of cleaning power under regular tap pressure with no pump required. Water enters the purifier through the pre-filter, which removes the chlorine and other chemicals. It flows through the reverse osmosis (RO) membrane which removes approximately 85% of the total dissolved solids (TDS). From there it enters the deionization (DI) filter which polishes the water and brings the TDS level down to or close to 0. This process provides 100% spot free water for cleaning and rinsing. It eliminates spots from occurring on the glass. In addition, it provides purified water for a much longer time than regular DI filters, before filters are required to be changed. Note - It does remove pre existing water stains. If this issue is prevalent a chemical clean is required.
Magnum 3 Stage Purifier operating manual 1. On first operation, flush the RO for 10 minutes minimum and let RO saturate overnight. Flush mode has the valve set at 12 o’clock positition. (see photo) Important: to prevent premature wearing on the RO membrane, flush for 5 minutes at the end of each work day. and 2 o’clock. (see photo) 2. When cleaning windows, have valve set between 1 o’clock and 2 o’clock. (see photo) Flush at end of each work day. Set valve between 1-2 o’clock 1-2 o’clock for cleaning window
1) Run water into the system for 10 minutes and leave water in the system to saturate the RO, allow the membrane to saturate for up 12 hours for the best results 2) Connect a garden hose to the inlet of the pre-filter part, no valve open or close, in a few minutes the system will pressurize and begin creating pure water. 3. Accessories: 1) Stainless steel membrane housing 1pcs 2) Romembrane1pcs 3) 10*4.5 big blue housing 1pcs 4) 10*2.5 filter housing 1pcs 5) 10*4.5 DI filter cartridge 1pcs 6) 10*2.5 sediment filter 1pcs 7) Big filter wrench 1pcs 8) Small filter wrench 1pcs 4. How&Whentochangethefilters: 1) Sediment filter: 3 month more or less 2) DI Resin filter: if the water TDS over 10ppm, the resin need to change 3) Ro membrane: Replace when the TDS of the permeate water(pure water) is only 80% of the incoming TDS